Lives International logo
 
Incubators





Lives International is dedicated to meeting the globally thermal validation needs of pharmaceutical and biotech industry, using innovation and creativity in developing new equipments and technology and improving the existing to fulfill our customers' expectations of reliability, efficiency and accuracy. We supply the Pharmaceutical and Biotech Industry with the most advanced technology for thermal validation and thermal mapping. We offer both thermocouple based systems and wireless dataloggers.
Lives validation systems incorporate the most advanced software developments for automated calibrations, reports and calculations.
All Lives validation systems are FDA and 21 CFR Part 11 compliant.
Whats New
XpertVal System
XpertLog System
Temperature Blocks
Reference Probes
Thermocouples
Equipment Rentals
cGMP Calibrations
Contract Validation
Training

 


HEADQUARTERS


North America:
USA

99, Pine Hill Rd
Nashua, NH 03063
Ph: +1 603-821-1898
Fax: +1 603-821-1888


Canada
1751 rue Richardson,
suite 8207,
Montréal, Qc, H3K 1G6

Europe:
France

3, rue Jules Guesde
92300 Levallois Perret
Ph: +33 142 708 589
Fax: +33 142 708 744


Romania
Str Lucian Blaga nr. 1
300001 Timisoara
Ph / Fax: +40 356 174249

Incubators
 

Incubation is the process of growing biological cultured material under a strictly controlled environment. Typically, the controlled variables are temperature and humidity but may also include CO2 and UV light.

The Lives XpertLog wireless dataloggers would be the best choice for this application if temperature and humidity are the only measurements needed. The time savings over thermocouple based systems is significant (See chart).

The XpertLog wireless dataloggers were designed for incubator mappings. The temperature datalogger has a range of -60 C to 150 C with a calibrated accuracy of +/-0.1 C. The RH datalogger has a calibrated range of 20% to 90% with an accuracy of +/- 2%. The XpertLog RH  datalogger is uniquely calibrated for all ICH  temperature points*.

*Note: RH measurements vary with temperature so calibration at specific ICH temperature points are necessary to maintain accuracy. Most other RH dataloggers are only calibrated at 25 C. If used for 40 C stability studies then a special calibration is required. Otherwise, the RH measurement error can easily exceed the ICH limit of +/- 5%.

If CO2 or UV light measurements are required in addition to temperature & humidity, then a thermocouple based system will be necessary to log all the data together**. In this case, the Lives XpertVal thermocouple based system would be recommended. The XpertVal system  can accept  CO2 and UV light transducers with 4-20mA or 1-5V outputs.

**Note:
Wireless dataloggers are not available with CO2 or UV light sensors since the power requirements are too high for datalogger batteries.

 
 