Xpertlog® LMS covers local monitoring applications between -200°C to +400°C (RTD sensor range)
User friendly: easy setup, swipe to add loggers, 2D/3D view, alarms, email warnings, pre-calibration not needed
Real time data transmission
Data loggers powered by batteries and/or power supply
High accuracy: ±0.1°C from -200°C to +140°C.
Data integrity: FDA 21 CFR Part 11

Characteristics LMS T  
Sensor element 4 wires PT-100
- flexible - 1000mm (39”) PTFE
- customized - up to 3000mm (10')
Operating Range
- measurement (sensor) -200°C to +400°C
- operating (logger's body) -40°C to +85°C
Accuracy ±0.1°C from -200°C to +140°C
Memory capacity 32,000 data points
Sampling rate 1 sec to 24 hours
Internal clock drift 4 sec / 24 h @ 23 °
Mechanical
- weight 95 g (3.35 OZ)
- diameter 40 mm (1.57")
- height 55 mm (2.17")
Power External
2 x Lithium batteries
0.35 g/each Lithium content
classified UN3091 under IATA DGR section 3.9.2.6
compliant with ICAO/IATA packing instructions 970
user replaceable
Battery lifetime Up to 6 months, based on usage
Wireless range 400 feet (121 m)
Radio frequency 2.4 Ghz ISM band
Access Point USB connection
Calibrations Factory:
User:
traceable NIST/COFRAC - ITS-90 coefficients stored in the internal memory
close loop calibration, using XpertLog® software
Certification FMC:
RF:
Health Safety:
EN 60601-1-2 / 2007
EN 300440-2 v1.3.1 (2009-03)
EN 60950-1 / 2006
  • LMS RH
    LMS RH XpertLog® LMS covers local monitoring applications between -200°C to +400°C (RTD sensor range) User friendly, easy setup, swipe to add…
  • LMS T - Wireless Temperature Data Logger
    LMS T - Wireless Temperature Data Logger Wireless Temperature Data Logger. XpertLog® LMS covers local monitoring applications between -200°C to +400°C (RTD sensor range) User friendly, easy…
  • Pliers
    Pliers Tools to open loggers for battery replacemenet.
  • Bracket
    Bracket Mounting bracket for standard and RF data loggers
  • Docking Station
    Docking Station Docking Station for GMP and GDP data loggers
  • Activation Point
    Activation Point Activates GMP RF and LMS wireless dataloggers
  • Repeater
    Repeater Repeater to extend the coverage area of the Access Point
  • GMP Pipe
    GMP Pipe Adapter for fixing data logger’s sensor inside pipes
ISO 9001:2008

ISO 9001:2008

ISO 14001:2004

ISO 14001:2004

OHSAS 18001:2007

ISO 18001:2007

Read 345 times
More in this category: LMS RH »

Leave a comment

Offices

USA
1 Chestnut Street
Nashua, NH 03063
CANADA
7240 Waverly, Suite 209
Montreal QC H2R 2Y8
CHINA
1511, Building B, No.15 Changyi Road,
Shanghai 200439
UNITED KINGDOM
235-237 Vauxhall Bridge Road
SW1V 1EJ London
FRANCE
3 rue Jules Guesde
92300 Levallois Perret
ROMANIA
37 Bela Bartok
Dumbravita 307160, jud. Timis
GERMANY
15 Carl-Legien-Str.
Gebäude B, 63073 Offenbach-Waldhof

UPCOMING EVENTS