XpertVal® is a conventional thermocouple based system for thermal mapping and validation
Highly efficient: Tc wires are installed on 3x20 channels module with cold junction compensation
Highly reliable: rugged data logger used in industrial harsh environment real time data display
Accurate: high accuracy of Tc after pre-calibration (±0.2°C)
Data integrity: FDA 21 CFR Part 11 software

Characteristics GMP RF  
Sensors Thermocouples
Sensor length -standard: 10 m (33 feet)
Sensor type all type of thermocouples, most used: T, J, K
Temperature range - teflon: -200°C to +200°C
- kapton: -200°C to +400°C
Accuracy ±0.2°C after pre-calibration
Memory capacity no limitation, data is stored in computer
backup memory: USB storage device compatible
Tc Tip teflon: teflon tip to prevent moisture on the wire
kapton: no tip
Sampling rate typical: 10 sec. for 20 channels (high resolution)
fast scan: 2 sec. for 20 channels (low resolution)
Software 21 CFR Part 11
Module the module accepts several inputs: 4 - 20 mA / 0-10 V / RTD (PT-100 2, 3 or 4 wires)
Close loop calibration always needed when using thermocouples
system use temperature block and reference probe, software controlled
reports generated automatically by the software
Reference probe IRTD
Hart 1502
Dry blocks PTC 125: -90°C to +125°C
RTC 157: -45°C to +155°C
RTC 159: -100°C to +155°C
RTC 700 : +23°C to +700°C
Fluke 9190: -90°C to +140°C
Fluke 9170: -45°C to +140°C
Fluke 9172: +35°C to +425°C
Calibrations Factory: NIST/COFRAC
User calibration

Thermocouple Systems

  • XpertVal®
    XpertVal® XpertVal® is a conventional thermocouple based system for thermal mapping and validation. Thermocouples are installed…

XpertVal Accessories

ISO 9001:2008

ISO 9001:2008

ISO 14001:2004

ISO 14001:2004

OHSAS 18001:2007

ISO 18001:2007

Read 468 times

2 comments

  • Comment Link Lives International Thursday, 12 October 2017 13:37 posted by Lives International

    The XpertLog Software can integrate the data from thermocouples,
    standard data loggers and wireless RF data loggers.

    The data obtained can be displayed in a 3D view and then saved in a 3D report.

    The XpertLog Software can be used with a wide range of blocks
    and reference probes from multiple manufacturers.

    You can also create acceptance criteria that will automatically
    do the calculations for your validation and the interface is user friendly.

  • Comment Link Husam Joudeh Monday, 15 May 2017 10:57 posted by Husam Joudeh

    Dears'

    I need to know the differences between the Xpertlog software and the TQSoft software from Fluke, both software are 21 CFR Part 11 compatible and used for thermal mapping logging with Hydra loggers and dry blocks ???

    why should I buy Xpertlog not TQSoft?

    I already worked with the Xpertlog software

    Best Regards

Leave a comment

Offices

USA
1 Chestnut Street
Nashua, NH 03063
CANADA
7240 Waverly, Suite 209
Montreal QC H2R 2Y8
CHINA
1511, Building B, No.15 Changyi Road,
Shanghai 200439
UNITED KINGDOM
235-237 Vauxhall Bridge Road
SW1V 1EJ London
FRANCE
3 rue Jules Guesde
92300 Levallois Perret
ROMANIA
37 Bela Bartok
Dumbravita 307160, jud. Timis

UPCOMING EVENTS