GMPF RF 10R SS






                          Real Time Temperature Data Logger  -60 to +85°C






                                 +    Collects and transmits real time temperature to XpertLog Software
                                 +    ITS-90 calibration coefficients are stored in the internal memory
                                 +    Complies with FDA 21 CFR Part 11
                                 +    Network ready: multiple users, centralized, server database, active directory authentication
                                 +    Calibration can be performed on site
                                 +    Can be remotely activated







                                                                  ø 25.00mm
                                                                      0.98″
                                  46.00mm / 1.81″









               Sensor type        4 wires thin
                  - flexible      150 mm (6”) or custom length
                  - sensor size   1.2 x 2.8 mm (0.05 x 0.11”)
                                       2
                  - cross section   1.13 mm  (0.00175 inch )                  Order Reference:
                                                  2
               Operating Range
                  - body temp.    -60°C to +85°C                              GMPF_RF_10R_SS_4W_THIN
                  - sensor temp.   -80°C to +140°C
               Accuracy           ±0.1°C from -60 to +85°C
               Resolution         0.01°C
               Memory capacity    32,000 data points
               Sampling rate      1 sec to 24 hours
               Transmission       Simultaneous: maximum 20 loggers
                                  Sequential: unlimited
               Internal clock Drift    4 sec / 24 h @ + 23 °C
               Mechanical                                                        Standard Calibration Points
                  - material      Peek 1000 - FDA compliant
                  - enclosure     IP-68                                                       • -60°C
                  - weight        24 g (0.85 oz)
                  - diameter      25 mm (0.98”)                                               •  0°C
                  - height        46 mm (1.81”)
               Power              1 x Lithium battery, 0.35 g Lithium content classified
                                  UN3091 under IATA DGR section 3.9.2.6 compliant with        •  85°C
                                  ICAO/IATA packing instruction 970 user replaceable
               Battery lifetime   Up to 2 months, based on usage
               Antenna            Internal
               Wireless range     121 m (400’)
               Radio frequency    2.4 GHz ISM band
               Access point       USB to computer
                                  Programs and reads unlimited number of loggers
               Calibrations       Factory:               Traceable NIST / COFRAC - ITS-90 coefficients reside in the internal memory
                                                                              ®
                                  User:                    Closed loop user calibration, using XpertLog  Software
                                                                                                                      GMPF RF 10R SS
               Certification      EMC:                    EN 60601-1-2 / 2007
                                  RF:                       EN 300440-2 v1.3.1 (2009-03)
                                  Health & Safety:      EN 60950-1/2006