GMP RH RF







                            Real Time Humidity Data Logger  0-100% RH





                               +    Collects and transmits real time humidity and temperature to XpertLog Software
                               +    ITS-90 calibration coefficients are stored in the internal memory
                               +    Complies with FDA 21 CFR Part 11
                               +    Network ready: multiple users, centralized, server database, active directory authentication
                               +    Can be remotely activated







                                   33.00mm    1.30″  62.00mm



                                   29.00mm    1.14″    2.44″




                                                                                            Order Reference:
                Sensor type        RH: capacitive / Temp: 4 wires  PT-100
                   - rigid         20 mm (0.8”)
                   - temp. sensor size   1.5 x 8 mm (0.06 x 0.315”)                         GMP-RH_RF
                   - temp. cross section   1.77 mm  (0.0027 inch )
                                                  2
                                         2
                Operating Range
                   - humidity      0 to 100% RH non condensing
                   - body temp.    -40°C to +100°C
                   - sensor temp.   -40°C to +100°C                                 Standard Calibration Points
                Accuracy           ±2.0% RH, 0% to 100% non condensing at 20°C to 45°C
                                   ±0.1°C from -40 to +100°C
                Resolution         0.01% RH; 0.01°C                                       •       25° C / 20%RH
                Memory capacity    16,000 data points humidity / 16,000 data points temperature
                Sampling rate      1 sec to 24 hours                                      •       25° C / 45%RH
                Transmission       Simultaneous: maximum 20 loggers                       •       30° C / 65%RH
                                   Sequential: unlimited
                Internal clock Drift    4 sec / 24 h @ + 23 °C                            •       40° C / 75%RH
                Mechanical
                   - material      Peek 1000 - FDA compliant                              Upon special request:
                   - enclosure     IP-51
                   - weight        95 g (3.35 oz)                                         •       45° C / 90%RH
                   - diameter      65 mm (2.56”)
                   - height        62 mm (2.44”)
                Power              2 x Lithium batteries, 0.35 g/each content classified
                                   UN3091 under IATA DGR section 3.9.2.6 compliant with
                                   ICAO/IATA packing instruction 970 user replaceable
                Battery lifetime   Up to 6 months, based on usage
                Antenna            Internal
                Wireless range     121 m (400’)
                Radio frequency    2.4 GHz ISM band
                Access point       USB to computer
                                   Programs and reads unlimited number of loggers
                Calibrations       Factory:               Traceable NIST / COFRAC - ITS-90 coefficients reside in the internal memory
                                                                               ®
                                   User:                    Closed loop user calibration, using XpertLog  Software
      GMP RH RF                    RF:                       EN 300440-2 v1.3.1 (2009-03)
                                   EMC:                    EN 60601-1-2 / 2007
                Certification
                                   Health & Safety:      EN 60950-1/2006