AMETEK blocks
RTC Dry Blocks
Lives International includes the most advanced and accurate temperature calibrators from Ametek in our thermal
validation system. Xpertlog software controls the temperature blocks and reference probes during close loop
calibrations. The calibration report is automatically generated after a calibration, contains the Id of the blocks and
reference probes.
The RTC Series also feature active dual - and triple - zone temperature control which provides excellent
temperature homogeneity in the well.
Name Reference Range Stability Delivered Ref. probe
with
RTC-156A
Dual zone RTC-156A_Lives_230A_NON_CT -30 to 155 °C
heating dry RTC-156A_Lives_115B_NON_CT -22 to 311 °F ± 0.005 °C - Internal
block
RTC-156C - Accredited
Dual zone RTC-156C_Lives_230A_NON_DLC_R2_915_HS_CT -30 to 155 °C ± 0.005 °C System - External (-60°C-160°C,
DLC sensor STS200A915) &
heating dry RTC-156C_Lives_115B_NON_DLC_R2_915_HS_CT -22 to 311 °F Calibration - Internal
block
RTC-157A
Dual zone RTC-157A_Lives_230A_NON_CT -45 to 155 °C ± 0.005 °C - Internal
heating dry RTC-157A_Lives_115B_NON_CT -49 to 311°F
block
RTC-157C - Accredited - External (-60°C-160°C,
Dual zone RTC-157C_Lives_230A_NON_DLC_R2_915_HS_CT -45 to 155 °C DLC sensor STS200A915
heating dry RTC-157C_Lives_115B_NON_DLC_R2_915_HS_CT -49 to 311°F ± 0.005 °C System ) &
Calibration
block - Internal
RTC-158A
Dual zone RTC-158A_Lives_230A_MXX_BAT_F_CT -22 to 155 °C
heating dry RTC-158A_Lives_115B_MXX_BAT_F_CT -8 to 311°F ± 0.02 °C - Internal
block & mini
oil bath
RTC-158C
Dual zone RTC-158C_Lives_230A_MXX_BAT_DLC_R2_916_HS_CT -22 to 155 °C ± 0.01 °C - Accredited - External (-60°C-160°C,
System
DLC sensor STS200A926) &
heating dry RTC-158C_Lives_115B_MXX_BAT_DLC_R2_916_HS_CT -8 to 311°F Calibration - Internal
block
RTC-159A
Ultra Low RTC-159A_Lives_230A_NON_F -100 to 155 °C ± 0.03 ˚C - Internal
Cooler Dry RTC-159A_Lives_115B_NON_F -148 to 311°F
Block
RTC-159C - Accredited - External (-100°C-160°C,
Ultra Low RTC-159C_Lives_230A_NON_DLC_R2_917_HS -100 to 155 °C ± 0.03 ˚C System DLC sensor STS200A917) & RTC
Cooler Dry RTC-159C_Lives_115B_NON_DLC_R2_917_HS -148 to 311°F Calibration - Internal
Block
All RTC dry blocks are delivered with carrying case with trolley. Insert is not included.
All C models ( ex RTC-157C) include an internal ref. probe and an external with 90° angled and 4 mm diameter.