Page 43 - Lives International Product Catalog 2019
P. 43

AMETEK blocks










               RTC Dry Blocks


















       Lives International includes the most advanced and accurate temperature calibrators from Ametek in our thermal
       validation system. Xpertlog software controls the temperature blocks and reference probes during close loop
       calibrations. The calibration report is automatically generated after a calibration, contains the Id of the blocks and
       reference probes.

       The RTC Series also feature active dual - and triple - zone temperature control which provides excellent
       temperature homogeneity in the well.


        Name                     Reference                     Range     Stability  Delivered     Ref. probe
                                                                                     with
      RTC-156A
      Dual zone          RTC-156A_Lives_230A_NON_CT          -30 to 155 °C
      heating dry        RTC-156A_Lives_115B_NON_CT          -22 to 311 °F  ± 0.005 °C      - Internal
      block
      RTC-156C                                                                    - Accredited
      Dual zone    RTC-156C_Lives_230A_NON_DLC_R2_915_HS_CT  -30 to 155 °C  ± 0.005 °C  System  - External (-60°C-160°C,
                                                                                            DLC sensor STS200A915) &
      heating dry   RTC-156C_Lives_115B_NON_DLC_R2_915_HS_CT  -22 to 311 °F        Calibration    - Internal
      block
      RTC-157A
      Dual zone          RTC-157A_Lives_230A_NON_CT          -45 to 155 °C   ± 0.005 °C     - Internal
      heating dry        RTC-157A_Lives_115B_NON_CT          -49 to 311°F
      block
      RTC-157C                                                                    - Accredited   - External (-60°C-160°C,
      Dual zone    RTC-157C_Lives_230A_NON_DLC_R2_915_HS_CT  -45 to 155 °C                  DLC sensor STS200A915
      heating dry   RTC-157C_Lives_115B_NON_DLC_R2_915_HS_CT  -49 to 311°F  ± 0.005 °C  System  ) &
                                                                                   Calibration
      block                                                                                 - Internal
      RTC-158A
      Dual zone        RTC-158A_Lives_230A_MXX_BAT_F_CT      -22 to 155 °C
      heating dry      RTC-158A_Lives_115B_MXX_BAT_F_CT      -8 to 311°F  ± 0.02 °C         - Internal
      block & mini
      oil bath
      RTC-158C
      Dual zone   RTC-158C_Lives_230A_MXX_BAT_DLC_R2_916_HS_CT  -22 to 155 °C   ± 0.01 °C  - Accredited  - External (-60°C-160°C,
                                                                                  System
                                                                                            DLC sensor STS200A926) &
      heating dry   RTC-158C_Lives_115B_MXX_BAT_DLC_R2_916_HS_CT  -8 to 311°F      Calibration   - Internal
      block
      RTC-159A
      Ultra Low           RTC-159A_Lives_230A_NON_F         -100 to 155 °C   ± 0.03 ˚C      - Internal
      Cooler Dry          RTC-159A_Lives_115B_NON_F          -148 to 311°F
      Block
      RTC-159C                                                                    - Accredited  - External (-100°C-160°C,
      Ultra Low     RTC-159C_Lives_230A_NON_DLC_R2_917_HS   -100 to 155 °C    ± 0.03 ˚C  System  DLC sensor STS200A917) &  RTC
      Cooler Dry    RTC-159C_Lives_115B_NON_DLC_R2_917_HS    -148 to 311°F         Calibration   - Internal
      Block



       All RTC dry blocks are delivered with carrying case with trolley. Insert is not included.
       All C models ( ex RTC-157C) include an internal ref. probe and an external with 90° angled and 4 mm diameter.


                                                                                                                   -43-


                   LVSC.3.1.6 - October 2019                                        Visit www.lives-international.com for more details.
   38   39   40   41   42   43   44   45   46   47   48