Low Temperature Real Time Wireless Data Logger with Flexible Sensor
Usable at -120°C

Wireless Data Logger GMP RF F 20R8V

-90°C to +85°C
-120°C up to 30 minutes

Xpertlog® GMPF RF 20R 8V low temperature data logger designed to fit between 20R vials.

Quote Request

Specifications for Low Temperature Real Time Wireless Data Logger with Flexible Sensor
Usable at -120°C Wireless Data Logger GMP RF F 20R8V

+ Real time data to XpertLog Software above -60°C
+ ITS-90 calibration coefficients are stored in the internal memory
+ Complies with FDA 21 CFR Part 11
+ Network ready: multiple users, centralized, server database, active directory authentication
+ Calibration can be performed on site
+ Can be remotely activated
Characteristics Order Reference: GMP-RF-F-20R8V LVSC.3.2.0 - January 2022
Sensor type 4 wires thin, teflon
- flexible 150 mm (6") or custom length
- customized up to 5000 mm (195”)
- sensor size 1.2 x 1.6 mm (0.05 x 0.06")
- cross section 0.48 mm² (0.0007 inch²)
- body -90°C to +85°C
-120°C up to 30 minutes
- sensor -200°C to +200°C

Before exposing the logger to temperatures below -90° C, the logger must stay for at least 3 hours at ambient temperature to allow warming to ambient
Accuracy ±0.1°C from -90°C to +85°C
±0.5°C at -196°C
Resolution 0.01°C
Memory capacity 32,000 data points
Memory type non volatile
Sampling rate 1 sec to 24 hours
Transmission simultaneus: maximum 20 loggers
sequential: unlimited
Internal clock drift 4 sec / 24 h @ 23°C
Mechanical
- material Peek 1000 - FDA compliant
Screws: 316L
- enclosure IP-64
- weight 230 g (8.11 oz)
- length 126 mm (4.96”)
- width
- height
52.25 mm (2.06”)
53.5 mm (2.09”)
Power Lithium battery


user replaceable
Battery lifetime Up to 6 months, based on usage
Antenna Internal
Wireless range up to 121 m (400 feet)
Radio frequency 2.4 Ghz ISM band
Access point USB to computer
Programs and reads unlimited number of loggers
Calibrations Factory Calibrations:
User Calibrations:
traceable NIST/COFRAC - ITS-90 coefficients stored in the internal memory
closed loop calibration using XpertLog® software
Standard Calibration Points • -196°C
• -80°C
• 0°C
• 85°C
Certifications EMC:
Health Safety:
RF:
FCC compliant
CE certified
EN 60601-1-2 / 2007
EN 60950-1 / 2006
EN 300440-2 v1.3.1 (2009-03)

Applications for Low Temperature Real Time Wireless Data Logger with Flexible Sensor
Usable at -120°C Wireless Data Logger GMP RF F 20R8V

Documents for Low Temperature Real Time Wireless Data Logger with Flexible Sensor
Usable at -120°C Wireless Data Logger GMP RF F 20R8V

Wireless Data Logger GMP RF F 20R8V Datasheet